📞 +91-7667918914 | ✉️ ijarcce@gmail.com
International Journal of Advanced Research in Computer and Communication Engineering
International Journal of Advanced Research in Computer and Communication Engineering A monthly Peer-reviewed & Refereed journal
ISSN Online 2278-1021ISSN Print 2319-5940Since 2012
IJARCCE adheres to the suggestive parameters outlined by the University Grants Commission (UGC) for peer-reviewed journals, upholding high standards of research quality, ethical publishing, and academic excellence.
← Back to VOLUME 2, ISSUE 7, JULY 2013

Low Cost Anesthesia Injector Based On Arm Processor

N.MANIKANDAN, S.MURUGANAND, K.VASUDEVAN M.Phil Scholar, Dept. Of Electronics and Instrumentation, Bharathiar University, Coimbatore, TamilNadu Assistant Professor, Dept. Of Electronics and Instrumentation, Bharathiar University, Coimbatore, TamilNadu Assistant Professor, Dept. Electronics and communication, V.L.B. Janakkiammal CAS, Coimbatore, TamilNadu

👁 40 views📥 0 downloads
Share: 𝕏 f in
Abstract: In the hospitals, any major operation is performed; the patient must be in anesthetizing condition. If the operation lasts for a long time, say for suppose for 4 or 5 hours, anesthesia cannot be give in a single stroke to the patient. Over dosage may cause a critical condition for the patient's towards death. If lower amount of anesthesia is to the patient, they may wakeup at the middle of the operation. Overcome this problem, the anesthetist administers few millilitres of anesthesia per hour to the patient in a particular time period. If the anesthetist fails to administer the anesthesia to the patient at the particular time interval. Overcome this problems the design of an automatic operation of an anesthesia machine based on a microprocessor is effective. In this system a keypad is provided along with the Microprocessor and syringe infusion pump. The anesthetist can set the level of anesthesia in terms of millilitres per hour to administer anesthesia to the patient with the help of keypad. when signal is received. After receiving the signal from the keypad, the Microprocessor controls the signal to the desire level and fed into the stepper motor to drive the infusion pump in proper manner. The anesthesia is administered to the patient according to the stepper motor rotation .if any uncertain condition the alarm will on.

Keywords: Patient, Anesthesia, Syringe, Processor, Stepper Motor.

How to Cite:

[1] N.MANIKANDAN, S.MURUGANAND, K.VASUDEVAN M.Phil Scholar, Dept. Of Electronics and Instrumentation, Bharathiar University, Coimbatore, TamilNadu Assistant Professor, Dept. Of Electronics and Instrumentation, Bharathiar University, Coimbatore, TamilNadu Assistant Professor, Dept. Electronics and communication, V.L.B. Janakkiammal CAS, Coimbatore, TamilNadu, “Low Cost Anesthesia Injector Based On Arm Processor,” International Journal of Advanced Research in Computer and Communication Engineering (IJARCCE)

Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License.